TŽK

This boiler is produced following the European guidelines given by the norm EN 303/5 and pressure equipment directive PED 97/23.
Construction of the boiler: Heating chamber is divided in two parts: Front storage part for fuel and back heat-exchanger part consisting of three vertical flue gas passes. The passage between first and second part is protected by the fireproof ceramic block;
Boiler has a manual cast-iron made cleaning system at the bottom above the ash tray. It comes with a thermometer on the front side.
It is made of 5mm thick steel (parts less exposed to high temperatures are 4mm).
Combustion is controlled via draught regulator (which is not a component part of boiler, must be ordered extra).
In order to achieve proper function of this boiler, a mixing valve is to be mounted on the return line (absolutely necessary). This model also requires a larger (higher) chimney compared to other models.
With correct installation and setting this boiler can burn autonomously up to 10 hours without fuel refill.
Type | 18 | 26 | 34 | 42 | 52 |
Overall power (KW) | 18 | 26 | 34 | 42 | 52 |
Weight (kg) | 320 | 349 | 390 | 440 | 503 |
Necessary draught (mbar) | 25 | 26 | 27 | 28 | 29 |
Max working temperature (°C) | 90 | 90 | 90 | 90 | 90 |
Max working pressure (bar) | 3 | 3 | 3 | 3 | 3 |
Water content (lit) | 89 | 125 | 145 | 165 | 187 |
Height (mm) | 990 | 1140 | 1140 | 1140 | 1270 |
Width (mm) | 650 | 650 | 750 | 850 | 850 |
Length (mm) | 1220 | 1270 | 1270 | 1270 | 1320 |
Flue diameter (mm) | ø160 | ø180 | ø180 | ø180 | ø180 |
Flue height (mm) | 947 | 760 | 760 | 885 | 912 |
Flow / Return (inch) | 5/4 | 5/4 | 5/4 | 5/4 | 5/4 |
Inner chimney diameter** (mm) | 200 | 200 | 200 | 200 | 200 |
Chimney height** (m) | 6-7 | 7-8 | 8-9 | 8-9 | 9-10 |
Heating area** (m²) | do 120 | 120-170 | 170-230 | 230-280 | 280-340 |
** Data given in the chart represents is a rough estimate only.