T-PRO

T-PRO (full name TKU3-W PRO) is made according to EN 303-5 and fulfills Ecodesign criteria 2015:1189.

Prescribed fuel for this boiler is firewood or coal with caloric value higher than 15 MJ/kg.

3-pass chamber construction with bottom heat exchanger (set of hot-water tubes) ensures high efficiency.

Size of the upper door and length of the boiler is carefully chosen to facilitate the load of longer wood-log pieces (up to 55cm).

Following the 303:5 norm demands, wall thickness of boiler plates in contact with water is 5 mm.

Boiler is equipped with a thermometer, removable ash-tray and cleaning kit. Boiler regulation is via draught regulator (to be purchased additionally).

Three-pass solid fuel boiler T-PRO is fully compatible with BIOTERMEC wood pellet burner for wood pellet combustion and it fulfills the requirements of the European norm EN 303/5 and 2015:1189.

The chamber and boiler housing come separate – the installer should mount the boiler housing on the spot.

TYPE202530354050
Boiler power (kW)202530354050
Power range (kW)15-2020-2525-3030-3535-4040-50
Weight (kg)235245265285310344
Necessary draught (Pa)192021222325
Max working temperature (°C)909090909090
Max working pressure (bar)333333
Boiler water volume (lit)9597102112117122
Height (mm)118511851185118511851185
Width (mm)505505550600650650
Lenght (mm)99010251025102510251100
Flue diameter (mm)ø160ø160ø160ø160ø180ø180
Flue height (mm)915915915915900900
Flow/return line (inch)5/45/45/45/45/45/4
Inner chimney diameter (mm)*ø200ø200ø200ø200ø200ø200
Chimney height (m)*6-77-87-88-99-1010-12
Heating area (m²)* <120 120-150150-180180-210210-240240-300

*this data is a rough estimate only. Consult your trusted installer and chimney expert.

Document title

Download

T-PRO 20-50 kW brochure SRB

T-PRO 20-50 kW Instructions for use and assembly SRB

Technical data
TYPE202530354050
Boiler power (kW)202530354050
Power range (kW)15-2020-2525-3030-3535-4040-50
Weight (kg)235245265285310344
Necessary draught (Pa)192021222325
Max working temperature (°C)909090909090
Max working pressure (bar)333333
Boiler water volume (lit)9597102112117122
Height (mm)118511851185118511851185
Width (mm)505505550600650650
Lenght (mm)99010251025102510251100
Flue diameter (mm)ø160ø160ø160ø160ø180ø180
Flue height (mm)915915915915900900
Flow/return line (inch)5/45/45/45/45/45/4
Inner chimney diameter (mm)*ø200ø200ø200ø200ø200ø200
Chimney height (m)*6-77-87-88-99-1010-12
Heating area (m²)* <120 120-150150-180180-210210-240240-300

*this data is a rough estimate only. Consult your trusted installer and chimney expert.

Download

Document title

Download

T-PRO 20-50 kW brochure SRB

T-PRO 20-50 kW Instructions for use and assembly SRB

Similar products:

TOP-W

three-pass steel boiler with fan regulation
25-50 KW