TOBY B
TOBY B is a wood pellet boiler made according to EN 303-5 that fulfills Ecodesign criteria 2015:1189. Boiler dimensions make it suitable for placement in smaller areas.
The boiler is offered in two versions. Standard and „SET version“. TOBY B SET has an 8-litre expansion vessel, a circulation pump, and a safety valve inside (beneath the back
cover). An air vent is not included.
Ignition, start-up and turning-off are fully automatized. Combustion control is optimized using algorithms such as ‘modulation’ which automatically decreases pellet dose as the difference between desired and reached temperature is decreasing.
Pellets are fed to boiler via internal transporter screw inside the storage tank. From there, pellets are fed over to heating chamber where they fall free to the designated combustion area (the ‘actual’ embedded burner of the boiler). Storage and combustion area are physically divided. There is a safety thermostat to prevent back-fire.
Buying an additional wi-fi router boiler can be turned on-off remotely via internet. Boiler regulation supports connection with ambient thermostat.
Buying an additional wi-fi router boiler can be turned on-off remotely via internet. Boiler regulation supports connection with ambient thermostat.

Default version of the product comes with a standard display
The premium touch-screen display can be ordered separately or at additional cost.
| TYPE | TOBY B 8 | TOBY B 12 | TOBY B 17 | TOBY B 21 | TOBY B 30 | TOBY B 40 | TOBY B 50 |
|---|---|---|---|---|---|---|---|
| Nominal power | 8 kW | 12 kW | 17 kW | 21 kW | 30 kW | 40 kW | 50 kW |
| Power range | 2 kW – 8,6 kW | 4 kW – 12 kW | 5 kW – 17 kW | 6 kW – 21 kW | 9 kW – 30 kW | 9 kW – 40 kW | 10 kW – 50 kW |
| Fuel consumption at min power | Min 0,65 kg/h | Min 0,8 kg/h | Min 1,1 kg/h | Min 1,3 kg/h | Min 1,4 kg/h | Min 2,7 kg/h | Min 3 kg/h |
| Fuel consumption at max power | Max 2,5 kg/h | Max 2,8 kg/h | Max 3,6 kg/h | Max 4,5 kg/h | Max 6 kg/h | Max 9 kg/h | Max 10 kg/h |
| Width (mm) | 565 | 565 | 615 | 635 | 735 | 790 | 790 |
| Height (mm) | 1465 | 1465 | 1465 | 1525 | 1525 | 1575 | 1575 |
| Lenght (mm) | 700 | 725 | 775 | 905 | 905 | 960 | 1020 |
| Flue gas exit height (mm) | 185 | 185 | 185 | 185 | 185 | 185 | 185 |
| Flow / Return (inch) | 1“ | 1“ | 1“ | 1“ | 1“ | 5/4“ | 5/4“ |
| Weight (kg) | 185 | 190 | 210 | 264 | 290 | 330 | 381 |
| Pellet storage capacity | 70 kg | 80 kg | 90 kg | 100 kg | 125 kg | 145 kg | 150 kg |
| Flue gas opening (mm) | ø80 | ø80 | ø80 | ø80 | ø80 | ø80 | ø80 |
| Air inlet (mm) | ø50 | ø50 | ø50 | ø50 | ø50 | ø50 | ø50 |
| Water volume (lit) | 33 lit | 33 lit | 41 lit | 58 lit | 78 lit | 96 lit | 104 lit |
| Flue gas exit temperature | <160 ºC | <160 ºC | <160 ºC | <160 ºC | <160 ºC | <160 ºC | <160 ºC |
| Energy consumption during start-up | 400 W | 400 W | 400 W | 400 W | 400 W | 400 W | 400 W |
| Energy consumption at steady-state | 100 W | 100 W | 100 W | 100 W | 100 W | 100 W | 100 W |
| Electrical network | 220V 50Hz | 220V 50Hz | 220V 50Hz | 220V 50Hz | 220V 50Hz | 220V 50Hz | 220V 50Hz |
| Boiler efficiency | >90 % | >90 % | >90 % | >90 % | >90 % | >90 % | >90 % |
- Technical data
-
TYPE TOBY B 8 TOBY B 12 TOBY B 17 TOBY B 21 TOBY B 30 TOBY B 40 TOBY B 50 Nominal power 8 kW 12 kW 17 kW 21 kW 30 kW 40 kW 50 kW Power range 2 kW – 8,6 kW 4 kW – 12 kW 5 kW – 17 kW 6 kW – 21 kW 9 kW – 30 kW 9 kW – 40 kW 10 kW – 50 kW Fuel consumption at min power Min 0,65 kg/h Min 0,8 kg/h Min 1,1 kg/h Min 1,3 kg/h Min 1,4 kg/h Min 2,7 kg/h Min 3 kg/h Fuel consumption at max power Max 2,5 kg/h Max 2,8 kg/h Max 3,6 kg/h Max 4,5 kg/h Max 6 kg/h Max 9 kg/h Max 10 kg/h Width (mm) 565 565 615 635 735 790 790 Height (mm) 1465 1465 1465 1525 1525 1575 1575 Lenght (mm) 700 725 775 905 905 960 1020 Flue gas exit height (mm) 185 185 185 185 185 185 185 Flow / Return (inch) 1“ 1“ 1“ 1“ 1“ 5/4“ 5/4“ Weight (kg) 185 190 210 264 290 330 381 Pellet storage capacity 70 kg 80 kg 90 kg 100 kg 125 kg 145 kg 150 kg Flue gas opening (mm) ø80 ø80 ø80 ø80 ø80 ø80 ø80 Air inlet (mm) ø50 ø50 ø50 ø50 ø50 ø50 ø50 Water volume (lit) 33 lit 33 lit 41 lit 58 lit 78 lit 96 lit 104 lit Flue gas exit temperature <160 ºC <160 ºC <160 ºC <160 ºC <160 ºC <160 ºC <160 ºC Energy consumption during start-up 400 W 400 W 400 W 400 W 400 W 400 W 400 W Energy consumption at steady-state 100 W 100 W 100 W 100 W 100 W 100 W 100 W Electrical network 220V 50Hz 220V 50Hz 220V 50Hz 220V 50Hz 220V 50Hz 220V 50Hz 220V 50Hz Boiler efficiency >90 % >90 % >90 % >90 % >90 % >90 % >90 % - Download