TOP-W
TOP-W (full name „Top Wood“) is made according to EN 303-5 and fulfills Ecodesign criteria 2015:1189.
Contrary to T-PRO, TOP-W is is a „force-draught“ boiler. Air regulation is done by the fan mounted on the back side, which is controlled by the regulation board located on top of the boiler. All other features are much similar to T-PRO.
Prescribed fuel for this boiler is firewood or coal with caloric value higher than 15 MJ/kg
3-pass chamber construction with bottom heat exchanger (set of hot-water tubes) is responsible for boiler high efficiency.
Size of the upper door and length of the boiler is carefully chosen to facilitate the load of longer wood-log pieces.
Following the 303:5 norm demands, wall thickness of boiler plates in contact with water is 5 mm
Boiler is equipped with a thermometer, removable ash-tray and cleaning kit.
Tip | 20 | 25 | 30 | 35 | 40 | 50 |
---|---|---|---|---|---|---|
Boiler power (kW) | 20 | 25 | 30 | 35 | 40 | 50 |
Power range (kW) | 15-20 | 20-25 | 25-30 | 30-35 | 35-40 | 40-50 |
Weight (kg) | 242 | 251 | 270 | 296 | 322 | 344 |
Necessary draught (mbar) | 19 | 20 | 21 | 22 | 23 | 25 |
Max working temperature (°C) | 90 | 90 | 90 | 90 | 90 | 90 |
Max working pressure (bar) | 3 | 3 | 3 | 3 | 3 | 3 |
Boiler water volume (lit) | 95 | 97 | 102 | 112 | 117 | 122 |
Height (mm) | 1185 | 1185 | 1185 | 1185 | 1185 | 1185 |
Width (mm) | 505 | 505 | 550 | 600 | 650 | 650 |
Lenght (mm) | 990 | 1025 | 1025 | 1025 | 1025 | 1100 |
Flue diameter (mm) | 160 | 160 | 160 | 180 | 180 | 180 |
Flue height (mm) | 1090 | 1090 | 1090 | 1090 | 1090 | 1090 |
Flow/return line (inch) | 5/4 | 5/4 | 5/4 | 5/4 | 5/4 | 5/4 |
Inner chimney diameter (mm)* | 200 | 200 | 200 | 160 | 200 | 200 |
Chimney height (m)* | 6-7 | 7-8 | 7-8 | 8-9 | 9-10 | 10-12 |
Heating area (m²)* | <120 | 120-150 | 150-180 | 180-210 | 210-240 | 240-300 |
*this data is a rough estimate only. Consult your trusted installer and chimney expert.
- Technical data
-
Tip 20 25 30 35 40 50 Boiler power (kW) 20 25 30 35 40 50 Power range (kW) 15-20 20-25 25-30 30-35 35-40 40-50 Weight (kg) 242 251 270 296 322 344 Necessary draught (mbar) 19 20 21 22 23 25 Max working temperature (°C) 90 90 90 90 90 90 Max working pressure (bar) 3 3 3 3 3 3 Boiler water volume (lit) 95 97 102 112 117 122 Height (mm) 1185 1185 1185 1185 1185 1185 Width (mm) 505 505 550 600 650 650 Lenght (mm) 990 1025 1025 1025 1025 1100 Flue diameter (mm) 160 160 160 180 180 180 Flue height (mm) 1090 1090 1090 1090 1090 1090 Flow/return line (inch) 5/4 5/4 5/4 5/4 5/4 5/4 Inner chimney diameter (mm)* 200 200 200 160 200 200 Chimney height (m)* 6-7 7-8 7-8 8-9 9-10 10-12 Heating area (m²)* <120 120-150 150-180 180-210 210-240 240-300 *this data is a rough estimate only. Consult your trusted installer and chimney expert.
- Download